The Ethicon GEN11 Endo-Surgery generator combines advanced technology, multifunctionality and touchscreen simplicity in one sleek and easy-to-operate unit. No matter what the procedure or which Ethicon device you plan to use, the Ethicon Endo-Surgery generator will be the only power source you’ll need. This unit supports Harmonic Ultrasonic and Enseal Advanced Bipolar Devices.


Description
  • Universal connector and automatic instrument recognition.
  • Touchscreen for easy setup and operation.
  • High-resolution display with wider viewing angles.
  • Compact design takes up less space in the OR.
  • Software updates available via USB memory stick.

PDF DEL PRODUCTO

Additional information
MARCA

Ethicom

CONDICIÓN

Reacondicionado Certificado

Más Información

Más Información

Ethicon GEN11 Generator Specifications

Dimensions (Generator)

  • Height: 7.5 in (13.6 cm)
  • Width: 14.8 in (35.5 cm)
  • Depth: 13.7 in (35 cm)
  • Weight: 13 lbs (5.9 kg)

Dimensions (Cart)

  • Height: 37.5 in (95.3 cm)
  • Width: 22.1 in (56.2 cm)
  • Depth: 18.9 in (48 cm)
  • Weight: 37 lbs (16.8 kg)

Dimensions (Footswitch)

  • Height: 4.1 in (10.4 cm)
  • Width: 13.45 in (34.2 cm)
  • Depth: 7.5 in (19 cm)
  • Weight: 8 lbs (3.6 kg)

Enseal Output

  • Bipolar, no neutral electrode required
  • 100 VAC RMS maximum
  • 135 watts maximum (rated load 15 ohms, unless otherwise specified in the instrument IFU)
  • 300 – 490 kHz (330 kHz, unless otherwise specified in instrument IFU)

Harmonic Output

  • 150 VAC RMS maximum (Unless otherwise specified in the instrument IFU)
  • 35 watts continuous (Unless otherwise specified in the instrument IFU)
  • 30 – 80 kHz (55.5 kHz unless otherwise marked in instrument IFU

Power

  • Main Input: 100–240 V, 50/60 Hz, 500 VA
  • Main Fuses: T5AL 250 V (Time-delay, 5 Amp, glass body, 5x20mm package size, quantity: 2)

Ambient Operating Conditions

  • Temperature: 59°F–80.6°F, 15°C–27°C
  • Humidity: 30%–75% non-condensing
  • Atmospheric Pressure Range: 700 hPa–1060 hPa

Transport and Storage Conditions

  • Temperature: -31°F–129.2°F, -35°C–+54°C
  • Humidity: 10%–95% non-condensing
  • Atmospheric Pressure Range: 700 hPa–1060 hPa

Protections / Classifications

  • Degree of Protection Against Electric Shock: Type CF applied part consisting of the Harmonic or Enseal instruments
  • Class of Protection Against Electric Shock: Class 1
  • Ingress Protection G11 Enclosure: IP21
  • Ingress Protection G11 Fotswitch: IP68